2017-04-17T05:15:23
Solar Inverter Manufacturer & Exporter In Nigeria
S.R.Electronics manufacturing pure sine wave inverter using copper wounded transformer maintaining minimum no load loss so that ensuring a great energy saver products also in comparison to other sine wave inverter of other brands which use aluminium wounded transformers.
ALTEK SOLAR INVERTER (TECHNICAL SPECIFICATIONS
Technology • intelligent UPS, USING IGBT Technology
• Microcomputer chip based
Latest Design • High Frequency, (Greater than 17.5 Khz) to ensure
Switching Frequency • Low Switching Lossess
• Purity of Sine-Wave
• Ultra-fast Transient Response
• Very Low Noise
Accurate Output • 415 V AC ±1.0% (Three Phase) or 230 V AC ±1.0% (single phase) 50 Hz +0.1% (Crystal Controlled)
Ratings • 1.0 -60.0 KVA
Output Power Factor • 0.8 lagging to unity and Also available in unity power factor above 7.5 KVA / 360 V DC.
Transient Response • for 100% step load change output stays within ±5% and Recovers within ½ cycle
Metering • On-board Programmable LCD/ Digital Panel meter to
display following parameters
• Output Voltage
• BatteryCurrent
• Battery Voltage
• Output Current
• Output Frequency and Various conditions/Parameter of UPS.
Wave Form • Pure Sine Wave
Distortion • Total Harmonic Distortion less than 2% for linear
load.
• Harmonic Distortion less than 5% for non-linear load
Overload Rating • 100% Continuous 150% for 30 seconds
Operating Temperature • 0 to 50o C 95% R.H. (Maximum)
Inverter Efficiency • Better than 90%
Transfer Time • Zero
Genset Compatibility • UPS System is fully Compatible to any type of
Genset
Protections • Output Over-Voltage
• Output overload
• Output Short Circuit
• Battery Under-Voltage
• Forced Air-cooling to protect electronic and other components from overheating.
Indications • Mains on, Charging, UPS on
• Load on UPS, Load on mains
• Battery low, UPS Trip
• Battery Low Alarm, Over Load
Alarms • Mains Fail (Alarm)
• Battery Low Warning (Alarm)
Low Noise • Less than or Equal to 45 dB (A) (Standard) at 1.0
mtr.
By pass Arrangement • In-built Solid-State Static-Switch provided
(For UPS of 7.5 KVA and above ratings)
• Manual changeover Switch provided
(For 1.0 to 10.0 KVA UPS Systems)
Useful Options • Synchronised/Asynchronised Inverter Configuration
• Critical / Non-Critical Redundant UPS
• Dual-Redundant (Hot Standby / Load Sharing)UPS Configuration
• Scott-Connected Transformer for Single phasing of Input AC Mains and stepping down the mains Voltage From 415 V to 270 V AC in bypass mode (Recommended for 10.0 KVA UPS and above with 3 phase input)
• Computer Interface ( Rs.-232) for Automatic Unattended Shutdown of file-server & Monitoring of Battery Status. Options available for Novell- LAN/NT-WINDOWS/SCO-UNIX/LINUX Remote control indications & Alarms Panel to Control the UPS functions from a distance.
Applications • For Computers, Lifts, Embroidery machines, Air conditions Single & Three Phase motors, Medical equipments etc.